Towards Structural Strength and Safety Evaluation Within Bridge Management Systems
Bridge management systems being implemented by transportation departments in the United States are limited in their ability to consider structural strength and safety when preparing recommendations...

Design of Lateral Steel in Columns
Lateral steel in columns is generally required for shear resistance, confinement of concrete and prevention of buckling of longitudinal bars. This paper is limited to the design of lateral...

Rational Limits for Longitudinal Steel in Concrete Columns
Current limits for the amount of longitudinal reinforcement in concrete columns were established more than 60 years ago. Commercial grades of reinforcement in 1930 were about half as strong...

High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...

Evaluation of Wood Floor Vibration Design Criteria
In the United States, floors in wood buildings are designed according to strength and deflection criteria under static uniform loads. With the introduction of engineered joist products...

Strength Variability of Wood Formwork Members
Failure of concrete formwork is one of the main causes of concrete construction failures. Among the main causes of formwork failure is inadequate strength. Currently there is no published...

Unified Code Provisions for Concrete Bridges
Provisions on limiting the flexural reinforcement adopted in the new AASHTO LRFD Specification for Bridge Design are summarized (1). They address minimum and maximum levels of reinforcement...

The Use of Coda Waves for Characterizing the Site Effect on Strong Ground Motion
The well established separability of source, path and site effects on coda waves of local seismic events offers the most effective means for determining the site amplification factor empirically....

Mechanical Behavior of Dowels Embedded in Concrete
In this paper an experimental investigation on the behavior of dowels embedded in concrete is described. The dowel strength under monotonic forces with two different boundary conditions...

A Self-Balancing Laminate
A self balancing wood laminate has been developed based on the principle of orthotropic elasticity. Lumber is cut into three sections in the flatwise plane and each side member is turned...

Metal Truss Plates: Less than Full-Depth Penetration and Shear Buckling
This paper presents the results of two experimental studies on metal truss plates which are used to join members of wood trusses. The first study investigated the effect that less than...

The Effects of Bolt Over-Tightening on Bolted Connections
This paper describes a portion of the research program being conducted on structural connectors which have been over-tightened. Direct-Tension Indicators (DTI) may be specified for use...

Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...

Seismic Strengthening of URM Buildings with Steel Bracing
Unreinforced masonry (URM) buildings with large open fronts are extremely vulnerable to seismic inputs posing serious life safety hazard. Steel bracing systems have been used to upgrade...

Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...

Biaxial Testing of Brittle Repair Material for Rigid Pavements
Most codes of practice prescribe procedures for selecting patch configuration and material based on test devised for evaluating new pavement materials. This study is aimed at examined...

Testing of Hollow Clay Tile Masonry Prisms
This paper presents test results of 610-mm wide (24-in.) by 1219-mm high (48-in) by 203- or 330-mm (8- or 13-in.) thick prisms constructed of hollow clay tiles. Three prisms were extracted...

Compressive Strength of Masonry Prisms
Many factors affect the estimation of compressive capacity of a masonry prism. In the study the effects due to grout strength, mortar joints, block geometry and size, moisture content,...

Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...

Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...

 

 

 

 

Return to search